Introduction 29
KIRK Wireless Server 600v3 Installation and Configuration Guide
2.2.2.2 Electrical Requirements
The following electrical requirements must be met:
• The max. radiated output power for the antenna is 10mW e.i.r.p/channel.
• The supplied power for the charger must be 110 V to 120 V ac nominal (or 220 V to
230 V ac nominal), 50/60 Hz.
2.2.3 KIRK Handsets
2.2.3.1 Environmental Requirements
• The area where the handset is used must be within the temperature ranges of 0°C and
40°C.
• For correct battery charging, the room temperature must be between 0°C and 25°C/
32°F and 77°F. Therefore, the handset must not be placed in direct sunlight. The
battery has a built-in heat sensor which will stop charging if the battery temperature
is too high.
• For battery information, refer to “” on page 67.
• The area where the handset is used must be between 20% and 80% non-condensing
relative humidity.